Tube and Finned Tube for Power Generation
Power plants buy tube for two jobs: recovering heat that would otherwise leave through the stack, and rejecting heat that has already done its work. Both are unforgiving about fouling and metal temperature.
What Fails First in Power Generation
Economizer banks blinding with ash
Fly ash bridges across continuous fins until the gas side pressure drop forces an outage.
Fins loosening in the hot gas path
Mechanically bonded fins lose contact pressure once metal temperature rises.
Condenser tubes pitting in cooling water
Chloride bearing cooling water attacks standard austenitic tube.
Retubing windows measured in days
Replacement tubes have to match the existing bundle exactly or the outage runs long.
Tube We Supply Into This Sector
H/HH Fin Tube
Split square fins welded in pairs, leaving a straight ash lane along the tube
Base tube diameter: 25 mm - 73 mm · Base tube wall thickness: 3.0 mm - 6.0 mm
Spiral Fin Tube
Continuously welded helical fin for boiler, economizer and flue gas duty
Base tube diameter: 15 mm - 70 mm · Base tube wall thickness: 2.0 mm - 15.0 mm
"G" Embedded Fin Tube
Fin strip rolled into a machined groove in the tube wall for permanent metal-to-metal contact
Base tube diameter: 16 mm - 80 mm · Base tube wall thickness: 1.65 mm - 4.0 mm
Duplex Stainless Steel Tube
Duplex and super duplex seamless tube and pipe to ASTM A789 and A790
Tube outside diameter: 1/2" - 3" (12 mm - 76.2 mm) · Tube wall thickness: 0.02" - 0.5" (0.5 mm - 12.0 mm)
Tubesheet
Drilled tube plate up to 5000 mm diameter and 750 mm thick
Maximum outside diameter: 5000 mm · Maximum thickness: 750 mmWhere It Goes
- Economizer and heat recovery banks in coal, biomass and gas fired boilers
- Air cooled condensers and cooler bundles
- Feedwater heaters and surface condensers
- Nuclear, thermal and geothermal plant heat exchanger units

How We Deliver Into This Industry
Tube, fin geometry and tubesheet are taken from one bundle drawing, which is what keeps a retubing job inside its outage window.
Production runs on 25 rolling and cold drawing machines plus 23 fin lines and machines, with hydro, eddy current, mechanical and chemical testing performed in house. The company holds ISO 9001:2015, CE certificate, Production licence for pressure pipe and ships to the European, American and Gulf markets.
Solutions
Related reading
Power Generation Questions
Which fin type do economizers usually take?
H or HH type where the flue gas carries ash, spiral where the gas is clean. Fin pitch is set from dust loading before the duty calculation fixes fin height.
Can you match tubes for an existing bundle during an outage?
Yes. Send the bundle drawing or a sample tube. Base tube size, fin geometry, fin pitch and finned length are matched to what is installed.
Which tube grade for chloride bearing cooling water?
Duplex or super duplex in most cases. The grade depends on chloride level, temperature and velocity.
Do you supply tubesheets for power plant exchangers?
Yes, up to 5000 mm outside diameter and 750 mm thick, drilled to the bundle layout.
Specify Tube for Power Generation
Send process data, bundle envelope and the standard you work to. We will come back with the geometry and grade that fit, and the ones that do not.
[email protected] · Tel 0086 512 58392615 · Monday to Saturday, 08:30 - 17:30 China Standard Time (GMT+8)