Tube and Finned Tube for HVAC and Refrigeration
Refrigeration and climate control bundles are built to a fixed envelope and a fixed price. The tube has to add surface without adding size, and keep doing it after years of thermal cycling.
What Fails First in HVAC and Refrigeration
Duty limited by shell side film
Chiller and evaporator bundles constrained by outside heat transfer, not by the shell.
No room for a bigger exchanger
Plant rooms and skids fix the envelope before the exchanger is selected.
Galvanic corrosion between fin and tube
Dissimilar metal pairs in condensate wetted service.
Coil fins loosening with cycling
Repeated start-stop duty relaxes a tension wound fin.
Tube We Supply Into This Sector
Low Fin Tube
Integral low fin rolled from the tube wall itself, for shell and tube exchangers
Base tube diameter: 12.7 mm - 31.8 mm · Base tube wall thickness: 1.65 mm - 3.0 mm
L/LL/KL Fin Tube
Tension-wound foot fin in three footprint styles, the standard choice for air cooled heat exchangers
Base tube diameter: 19 mm - 51 mm · Base tube wall thickness: 1.65 mm - 3.0 mm
Extruded Fin Tube
Bimetal tube with the fin extruded from an outer sleeve, giving a seamless fin-to-tube wall
Base tube diameter: 10 mm - 51 mm · Base tube wall thickness: 1.65 mm - 3.0 mm
Stainless Steel Tube
Austenitic and super austenitic seamless tube and pipe to ASTM A213, A269 and A312
Tube outside diameter: 1/2" - 3" (12 mm - 76.2 mm) · Tube wall thickness: 0.02" - 0.5" (0.5 mm - 12.0 mm)Where It Goes
- Shell and tube chillers and evaporators
- Air cooled condenser coils
- Heating and ventilation batteries
- Compressor coolers

How We Deliver Into This Industry
Integral low fin tube retubes an existing shell without changing the tubesheet drilling, which is the fastest way to raise duty on installed plant.
Production runs on 25 rolling and cold drawing machines plus 23 fin lines and machines, with hydro, eddy current, mechanical and chemical testing performed in house. The company holds ISO 9001:2015, CE certificate, Production licence for pressure pipe and ships to the European, American and Gulf markets.
Solutions
Related reading
HVAC and Refrigeration Questions
How much surface does a low fin tube add?
The integral fin is 0.9 mm to 1.3 mm tall at 0.9 mm to 1.5 mm pitch, which multiplies the outside surface several times while still passing through conventional baffles.
Can we retube an existing exchanger with low fin tube?
Usually yes, because the plain bare ends and the tube outside diameter stay the same. Confirm the baffle clearance and the wall thickness under the fin root.
Which fin type for an air cooled condenser coil?
L type for general duty, extruded where the ambient atmosphere is corrosive.
Do you supply copper fin on copper tube?
Yes. Copper strip fin and copper base tube are both available.
Specify Tube for HVAC and Refrigeration
Send process data, bundle envelope and the standard you work to. We will come back with the geometry and grade that fit, and the ones that do not.