AC LED Modules manufactured by Shenzhen Jinda Shun Technology Co., Ltd.
Programme

Retrofitting a Sign With No Room for a Driver

What changes when the module runs straight off mains, and the three things that have to be checked before it can.

Retrofit work is constrained by a cavity somebody else built. When there is no space, no access or no appetite for a DC driver inside that cavity, the two AC models remove it entirely - along with the component that most often brings the maintenance van back.

Stage By Stage

Retrofitting a Sign With No Room for a Driver In 5 Steps

Confirm the mains voltage at the sign

A 120 V module on a 220 V feed is a one-second failure.

Both AC models are published for AC 120 V and AC 220 V. Which one you order is decided by the supply that is actually present.

Check the cavity depth against the two bands

Losing the driver does not change the optics.

The 6616B/AC publishes 80 to 120 mm, the 3939B/AC publishes 120 to 200 mm. Outside those, the retrofit needs a different approach.

Plan the run against the cascade limit

Mains voltage does not remove the published cascade limit.

Both models publish 20 modules single-ended and 50 double-ended.

Provide switching and protection to local code

Direct AC drive moves the electrical responsibility into the sign.

Mains still has to be brought, switched and protected at the sign position by someone qualified to do it.

Accept the published warranty difference

Assuming five years on a three year product is an expensive assumption.

The AC models publish a three year warranty. The DC range publishes five. That is the manufacturer's own figure and it is not negotiated here.

Questions

Retrofitting a Sign With No Room for a Driver Questions

Can I mix AC and DC modules on one sign?
Not on one circuit. They can appear on one sign only as separately fed, separately protected runs.
Is an AC module less efficient?
On these sheets, yes: both AC models publish 80 lm/W against up to 170 lm/W on the DC range. The trade is efficiency for the removal of the driver.

Start On Retrofitting a Sign With No Room for a Driver

Send the reference, the quantity and the destination market. A recommended starting point with the matching specifications comes back by email.