IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 Post Insulator

GOST ceramic post insulator for 10 kV line supports, 54 mm diameter, 272 mm high, 75 kV minimum puncture voltage, strength class II, UKhL2 climatic execution.

Post Insulators production

  • Home
  • Products
  • Post Insulators
  • IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 Post Insulator

Product Overview

A GOST ceramic post insulator used to fix conductors and cables to line supports at 10 kV. The body is 54 mm in diameter and 272 mm tall with a minimum puncture voltage of 75 kV, strength class II and UKhL2 climatic class. It is supplied under both the IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 designations, which appear on different CIS drawing sets for the same mounting envelope.

Why Buyers Choose This Part

  • Covers two GOST designations with one mounting envelope
  • 75 kV minimum puncture voltage on a 10 kV rated body
  • Slim 54 mm body fits crowded support brackets
  • Quality ceramic that holds its insulation through freeze and thaw cycles

Where It Is Used

  • 10 kV overhead line supports carrying conductors and cables
  • Distribution networks built to CIS drawing standards
  • Replacement on lines where the original designation is no longer stocked
  • Line construction projects that mix IO and IOR part callouts

Who It Suits

  • Overhead line contractors working to GOST drawings
  • Utilities in Russia, Belarus, Kazakhstan and neighbouring markets
  • Distributors consolidating CIS post insulator part numbers

What Goes Wrong Without The Right Part

  • Two drawing designations that buyers otherwise have to source separately
  • Post insulators that crack at the fixing after winter cycling
  • Conductors that work loose on the support because the insulator seat is wrong
  • Slow supply of GOST-pattern parts from local stock

How It Is Built

  • 54 mm body diameter
  • 272 mm overall height
  • 75 kV minimum puncture voltage
  • Strength class II
  • UKhL2 climatic execution
  • Quality electrotechnical ceramic body

Published Figures For This Product

Every value below comes from the manufacturer data for this item. Figures not listed are confirmed against the drawing before an order is placed.

Body Diameter54 mm
Overall Height272 mm
Minimum Puncture Voltage75 kV
Diameter54 mm

Materials

  • Electrotechnical ceramic body
  • Metal fixing hardware

Process

  • Body forming
  • Glazing
  • Firing
  • Hardware fitting
  • Puncture voltage test

Testing

  • Puncture voltage tested against the 75 kV minimum
  • Dimensional check on the 54 mm by 272 mm envelope
  • Glaze inspection before despatch

Certification

  • ISO 9001 quality management system

Customisation Options

  • Produced to customer drawings and samples
  • Marking to the designation your drawing uses
  • Packing arranged for your shipping route

How It Compares

Pin type insulatorA post insulator is fixed rigidly to the support and carries cantilever load, while a pin type insulator seats on a spindle and is normally used where the conductor is tied on.
Composite post insulatorCeramic keeps a stable surface over decades of weather exposure and does not depend on a polymer housing staying hydrophobic.

Before You Order And After It Arrives

  • Check which designation your drawing calls out before ordering
  • Mount square to the support so the body is not loaded on one edge
  • Tie the conductor into the seat, do not rely on friction
  • Inspect the glaze after winter for frost damage at the fixing

IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 Post Insulator Questions

Related Products

Post Insulators

IO-10/4 UKhL3 Ceramic Post Insulator For Line Supports

Post Insulators

  • Diameter Body 54 mm
  • Height 272 mm
  • Minimum Puncture Voltage 75 kV

IPU-10/630-7.5 I UKhL1 Wall Bushing With Oval Flange

Post Insulators

  • Rated Current 630 A
  • Minimum Mechanical Bending Failure Load 7.5 kN
  • Rated Voltage 10 kV

J8-125 Post Ceramic Insulator 8kN Bending Strength

Post Insulators

  • BIL 125 kV
  • Bending Strength 8 kN
  • Maximum Shed And Outer Diameter 110 mm

C4-80 II 10kV Porcelain Post Insulator GOST

  • Minimum Mechanical Breaking Force 4 kN
  • Creepage Distance 300 mm
  • Torsion Strength 100 N.m

Related Cases Guides And Applications

Low Voltage Post Insulators Principles Applications And Selection

Overhead Line Contractors

Switchgear Manufacturers

Manufacturing To Your Drawing Or Sample

Selecting Creepage For The Pollution At Your Site

Quote For IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 Post Insulator

Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.

Product Photographs

IO-10/4 UKhL3 ceramic post insulator standing uprightIOR-10/3.75 II UKhL2 post insulator fixing detailIO-10/4 post insulator shed profile close upIO-10/4 UKhL3 ceramic post insulator on a plain backgroundIPU-10/630-7.5 wall bushing insulator with oval flangeJ8-125 white post ceramic insulator standing uprightC4-80 II 10kV porcelain post insulator standing upright

Related Products

C4-80 II 10kV porcelain post insulator standing upright

C4-80 II 10kV Porcelain Post Insulator GOST

C4-80 II GOST post insulator for 10 kV switchgear. 80 kV test voltage, 4 kN breaking force, 300 mm creepage, 100 N.m torsion, 2.75 kg, UKhL1 climatic execution.

View Details →

Request a Quote

We reply to every enquiry within one business day. Write to us directly by email or WhatsApp — both reach our sales desk immediately.