[email protected]+86-799-7618678

15kV To 33kV Fuse Cut Out Bushing Insulator

Porcelain fuse cutout bushing range from 15 kV to 33 kV. Creepage 220 mm to 660 mm, diameters 287 mm to 467 mm, cantilever 6.8 kN to 20 kN, IEC safety standards.

Fuse Cutout Bushings production

  • Home
  • Products
  • Fuse Cutout Bushings
  • 15kV To 33kV Fuse Cut Out Bushing Insulator

Product Overview

A porcelain fuse cutout bushing range covering 15 kV through 33 kV, published as a full dimensional table across fifteen figure numbers. Creepage runs from 220 mm up to 660 mm, main diameters from 287 mm to 467 mm, shed counts from 8 to 17 and net weights from 2.6 kg to 7.5 kg. Voltage classes span 15 kV, 25 kV, 24/27 kV and 33/36 kV with cantilever strengths from 6.8 kN to 20 kN.

Why Buyers Choose This Part

  • Fifteen figure numbers so the exact creepage and diameter can be matched
  • Creepage choices from 220 mm to 660 mm across the range
  • Voltage classes from 15 kV to 33/36 kV in one published table
  • Built to IEC safety standards with ANSI and AS figures also covered

Where It Is Used

  • Pole-mounted fuse cutouts across 15 kV to 33 kV networks
  • Utilities standardising cutout bushings across several voltage classes
  • Replacement where the installed figure number must be matched
  • Export projects covering IEC, ANSI and AS requirements

Who It Suits

  • Distribution utilities across several voltage classes
  • Cutout assemblers sourcing porcelain bodies
  • Distributors supplying the full fuse cutout bushing range

What Goes Wrong Without The Right Part

  • Cutout bodies that do not match the installed figure number
  • Creepage selection across a network with mixed pollution levels
  • Sourcing 15 kV through 33 kV classes from separate suppliers
  • Cantilever ratings chosen without reference to the published table

How It Is Built

  • Fifteen figure numbers from 72101 to 722302
  • Main diameter D from 287 mm to 467 mm
  • Diameter d from 87 mm to 155 mm
  • Height from 32 mm to 35 mm
  • Creepage distance from 220 mm to 660 mm
  • Voltage class 15 kV, 25 kV, 24/27 kV and 33/36 kV
  • Cantilever strength from 6.8 kN to 20 kN
  • Net weight from 2.6 kg to 7.5 kg
  • Shed number from 8 to 17
  • Companion RW11-10/100 and RW11-10/200 cutout ratings at 110 kV BIL and 42 kV withstand

Materials

  • Electrical porcelain body
  • Metal fittings

Process

  • Forming
  • Glazing
  • Firing
  • Fitting assembly
  • Electrical test

Testing

  • Creepage verified against the figure number in the table
  • Cantilever strength proof test
  • Dimensional check on diameter and shed count

Certification

  • Built to IEC safety standards
  • ISO 9001 quality management system

Customisation Options

  • Brand name as per customer requirements
  • Model number to order
  • Export carton or customised packing

How It Compares

The RW11-10 drop-out fuse cutoutThe RW11-10 listing is the complete open frame cutout at 10 kV with 100 A and 200 A ratings. This range is the porcelain bushing table across the wider 15 kV to 33 kV span.
Standard transformer bushingsA fuse cutout bushing carries the fuse assembly as well as the lead, which is why the table publishes cantilever strength alongside creepage.

Before You Order And After It Arrives

  • Identify the figure number on the installed unit before ordering a replacement
  • Select creepage from the site pollution class, not voltage alone
  • Check the cantilever strength column against the fuse carrier load
  • Confirm the shed count matches the profile you need

15kV To 33kV Fuse Cut Out Bushing Insulator Questions

Related Products

Wall Bushings And Other Insulators

BUCHA 24kV 160A HV Porcelain Bushing C-450

Wall Bushings And Other Insulators

  • Creepage Distance, Catalogued As C-450 450 mm
  • Diameter 105 mm
  • Height 550 mm

BUCHA 24kV 160A 450mm Ceramic Bushing Isolators

High Voltage Transformer Bushings

  • Creepage Distance 450 mm
  • Diameter 105 mm
  • Height 550 mm

24kV To 36kV HV Porcelain Transformer Bushing

High Voltage Transformer Bushings

DIN 42531 20NF250A Transformer Bushing Isolators

  • DIN 42531 20NF Pattern 250 A

Related Cases Guides And Applications

Transformer Bushing Selection A Guide For Engineers

What Is A High Voltage Transformer Insulator

How To Choose Creepage Distance For A Polluted Site

Power Utilities And Substations

Manufacturing To Your Drawing Or Sample

Selecting Creepage For The Pollution At Your Site

Quote For 15kV To 33kV Fuse Cut Out Bushing Insulator

Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.

Product Photographs

15kV to 33kV fuse cut out bushing insulatorFuse cutout bushing insulator shed profileFuse cut out porcelain bushing fitting detailFuse cutout bushing insulators grouped togetherPorcelain fuse cutout bushings in the factory yardFuse cut out bushing insulator viewed from aboveFuse cutout bushing insulators packed for exportBUCHA 24kV 160A high voltage porcelain bushingBUCHA 24kV 160A 450mm ceramic bushing isolator24kV to 36kV high voltage porcelain transformer bushingDIN 42531 20NF-250A transformer bushing isolators

Related Products

Request a Quote

We reply to every enquiry within one business day. Write to us directly by email or WhatsApp — both reach our sales desk immediately.