
1.2kV 160A Transformer Bushing Insulator
1.2 kV 160 A screw thread transformer bushing insulator in wet process porcelain, light grey glaze, with NBR gaskets, copper threaded rod and stainless fasteners.
View Details →Porcelain bushings that carry transformer winding leads through the tank wall, insulate them to ground and hold them in place. 42 products in production with published figures, made to IEC, DIN, EN, ANSI, AS, GB and GOST patterns.

Porcelain bushings that carry transformer winding leads through the tank wall, insulate them to ground and hold them in place.
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
Wall Bushings And Other Insulators
Low Voltage Transformer Bushings
Wall Bushings And Other Insulators
Screw Thread Transformer Bushings
Low Voltage Transformer Bushings
Fuse Cutout Bushings
Low Voltage Transformer Bushings
Low Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
Low Voltage Transformer Bushings
Low Voltage Transformer Bushings
Wall Bushings And Other Insulators
Wall Bushings And Other Insulators
High Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
Screw Thread Transformer Bushings
High Voltage Transformer Bushings
Fuse Cutout Bushings
High Voltage Transformer Bushings
Low Voltage Transformer Bushings
Low Voltage Transformer Bushings
Low Voltage Transformer Bushings
Screw Thread Transformer Bushings
Screw Thread Transformer Bushings
Screw Thread Transformer Bushings
Low Voltage Transformer Bushings
Low Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
Low Voltage Transformer Bushings
High Voltage Transformer Bushings
High Voltage Transformer Bushings
Bushings for the high voltage side of distribution and power transformers, from the 10kV class up to 36kV.
Bushings for the 1kV and 3kV winding side of distribution transformers, from 250A up to 4000A.
Bushings whose threaded stem takes the terminal connection directly, the arrangement used on ANSI terminal boards and smaller pole transformers.
Porcelain bodies and complete drop-out fuse cutouts for pole-mounted transformer protection from 10kV through 33kV.
Through-wall bushings, indoor bushing insulators and GOST pattern parts that fall outside the main transformer bushing families.
Terminal boards designed around one bushing pattern that the original supplier has discontinued
A line section or substation that keeps flashing over after every wet season
Engineers responsible for power systems often face the challenge of selecting the most suitable transformer bushings for their app
The high voltage transformer insulator is a physical barrier isolating the high voltage parts of a transformer from the lower volt
Voltage sets the minimum creepage. The air at the site sets the required one. This guide works through the figures published acros
Send the drawing, the pollution class at the site, or a photograph of the part you are replacing. A reply comes back within 24 hours.













1.2 kV 160 A screw thread transformer bushing insulator in wet process porcelain, light grey glaze, with NBR gaskets, copper threaded rod and stainless fasteners.
View Details →
1.2 kV 400 A screw thread transformer bushing in wet process porcelain with light grey glaze. NBR gaskets, copper threaded rod, brass connector, stainless fasteners.
View Details →
1.2 kV 800 A ANSI low voltage bushing with 30 kV BIL in wet process porcelain. Three connector options, NBR gaskets, copper threaded rod, stainless steel fasteners.
View Details →
Porcelain fuse cutout bushing range from 15 kV to 33 kV. Creepage 220 mm to 660 mm, diameters 287 mm to 467 mm, cantilever 6.8 kN to 20 kN, IEC safety standards.
View Details →
18 kV 25 A ANSI transformer bushing in the ANSI-18/50 body. 541 mm height, 480 mm creep distance, 8 single umbrella sheds, 3.5 kg, meets ANSI performance standards.
View Details →
EN 50386 outdoor transformer bushing at 1 kV and 2000 A, 75 mm creepage, 1.29 kg. Range covers 250 A to 4000 A. Metal parts, gaskets and porcelain supplied complete.
View Details →
High voltage porcelain transformer bushing covering 24 kV to 36 kV. Insulates leading wires and provides mechanical support inside the transformer. Made to drawing.
View Details →
24 kV outdoor porcelain transformer bushing, 150 kV BIL, 60 kV wet withstand, 453 mm high, 137 mm diameter, 8 kg. Made to drawing or sample, ISO 9001 factory.
View Details →
24 kV 160 A ceramic transformer bushing with 450 mm creepage, 105 mm diameter and 550 mm height. Second catalogue reference for the same C-450 bushing.
View Details →
24 kV 160 A transformer ceramic bushing with 450 mm creepage, 105 mm diameter and 550 mm height. Slim profile for crowded terminal boards, made to drawing or sample.
View Details →
DIN 10NF250A transformer bushing for oil-immersed distribution transformers. High alumina porcelain C110, grey brown or white glaze, brass rod or flexible wire condu
View Details →
DIN 20NF630A porcelain transformer bushing, 20/24 kV at 630 A, 440 mm creepage, 125 kV BIL, 385 mm high, 6.1 kg. Copper or aluminium conductor, made to drawing.
View Details →
DIN 24 kV 630 A porcelain transformer bushing with 525 mm creepage for coastal and polluted sites. 125 kV BIL, 385 mm high, 160 mm diameter, 6.8 kg net.
View Details →
DIN 42539 DT 3/630 outdoor transformer bushing, 3 kV at 630 A, 45 mm tank hole, 40 kV BIL, 120 mm creepage, M20 stem connection. Metal parts and gaskets supplied.
View Details →
DIN 42539 transformer bushing, 3 kV at 250 A, 120 mm creepage. Complete assembly with NBR gaskets, copper threaded rod, brass connector and stainless steel fasteners
View Details →
DIN 42530 DT 1/3150 transformer bushing, 1 kV at 3150 A, 90 mm tank hole, 75 mm creepage, M48 stem connection. Supports, insulates and fixes the LV winding lead.
View Details →
DIN 42530 low voltage transformer bushing, 1 to 3 kV at 1250 A, porcelain insulator with copper fittings. Export carton and wooden pallet packing, made to specificat
View Details →
DIN 42530 transformer bushing, 1 to 3 kV at 2000 A, 75 mm creepage, 1.29 kg. Porcelain insulator with copper fittings, export carton and wooden pallet packing.
View Details →
DIN 42530 DT 1/630 transformer bushing, 1 kV at 630 A, 45 mm tank hole, 75 mm creepage, M20 stem connection. Range covers 250 A to 3150 A with matching tank holes.
View Details →
DIN 42530 1NF250A low voltage transformer bushing ceramic insulator, 250 A, 50 mm creepage, 0.26 kg. Supports and insulates the LV winding lead in oil transformers.
View Details →
DIN 42531 10NF250A transformer bushing tested to IEC 60137. Range covers 1 kV to 52 kV and up to 5000 A with creepage distances for all environmental conditions.
View Details →
DIN 42531 20NF250A transformer bushing for the 20 kV class at 250 A. Alumina and mica porcelain shell, silicon steel core, electrolytic copper or aluminium conductor
View Details →
DIN 42531 30NF250A transformer bushing with alumina and mica porcelain shell, silicon steel core and electrolytic copper or aluminium alloy conductor.
View Details →
DIN 42539 transformer bushing at 3 kV and 1000 A with 125 mm creepage, for oil-immersed distribution transformers. Metal parts, gaskets and porcelain supplied comple
View Details →
EN 50180 transformer bushing at 24 kV and 250 A, manufactured and tested to IEC 60137. Range covers 1 kV to 52 kV and up to 12500 A with a wide choice of creepage.
View Details →
IO-10/4 UKhL3 and IOR-10/3.75 II UKhL2 post bushing insulator for 10 kV GOST assemblies. Made to drawing or sample with drawing figures confirmed before production.
View Details →
Porcelain drop-out fuse cutout for pole-mounted transformers. RW11-10/100 at 100 A and 6.3 kA, RW11-10/200 at 200 A and 12.5 kA, 110 kV BIL, 42 kV withstand, IEC.
View Details →
GOST 10 kV wall bushing ceramic insulator, 630 A rated, 80 kV lightning impulse test, 7.5 kN bending failure force, 300 mm leakage path, atmosphere types I and II.
View Details →
1 kV LV ANSI transformer bushing with 30 kV BIL in wet process porcelain, light grey glaze. NBR gaskets, copper threaded rod, brass connector, stainless fasteners.
View Details →
Threaded ANSI-18/50 transformer bushing, 541 mm height, 480 mm creep distance, 8 single umbrella sheds, 3.5 kg. Meets ANSI electrical and mechanical performance.
View Details →
EN 36/250/P3 transformer bushing insulator, 36 kV rated, 600 mm high, 155 mm diameter, 935 mm creepage, 465 mm arcing distance, 6.8 kg. For heavily polluted sites.
View Details →
GB B-1/315 low voltage transformer bushing insulator to Chinese National Standard. 1 kV rated, 105 mm high, 65 mm diameter, 85 mm creepage, 0.29 kg net weight.
View Details →
GB BLQ-10/315 transformer bushing insulator to Chinese National Standard. 10 kV rated, 240 mm high, 115 mm diameter, 180 mm creepage, 165 mm arcing distance, 1.7 kg.
View Details →We reply to every enquiry within one business day. Write to us directly by email or WhatsApp — both reach our sales desk immediately.