Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
Bestfil Syringe Filter product photo 1
Bestfil Syringe Filter product photo 2Bestfil Syringe Filter product photo 3Bestfil Syringe Filter product photo 4Bestfil Syringe Filter product photo 5
Syringe Filter

Bestfil Syringe Filter

Bestfil™ is a high-throughput syringe filter designed for routine sample preparation in HPLC, GC, and UV analysis. It features a 33 mm diameter housing made from MBS, offering a large filtration area of 5.3 cm² to handle high-volume or particle-laden samples without frequent replacement. The injection-moulded sealing ensures integrity under pressure, and the filter is available in both sterile and non-sterile forms. It is engineered as a direct replacement for Millipore's Millex syringe filters, maintaining compatibility with standard syringe fittings and lab workflows.

  • 33 mm diameter provides 5.3 cm² filtration area, suitable for high-volume or high-particulate samples
  • Injection-moulded sealing withstands 87 psi (6.0 bar) at 20°C, preventing housing failure during high-pressure filtration
  • Available in both sterile and non-sterile formats to match lab-specific requirements
  • Direct replacement for Millipore Millex syringe filters, enabling method continuity without revalidation
Key Benefits

What This Product Gives You

  • 33 mm diameter provides 5.3 cm² filtration area, suitable for high-volume or high-particulate samples
  • Injection-moulded sealing withstands 87 psi (6.0 bar) at 20°C, preventing housing failure during high-pressure filtration
  • Available in both sterile and non-sterile formats to match lab-specific requirements
  • Direct replacement for Millipore Millex syringe filters, enabling method continuity without revalidation
  • Automated assembly in a controlled environment ensures consistent quality and minimal contamination risk
  • 33 mm diameter housing with 5.3 cm² effective filtration area
  • MBS housing material with injection-moulded sealing technology
  • Pore sizes from 0.1 to 5.0 micron, including 0.70 and 1.0 micron options
  • Available in sterile and non-sterile forms
  • Female luer lock inlet and male luer slip outlet for standard syringe compatibility
  • Maximum operating pressure of 87 psi (6.0 bar) at 20°C
  • Automated assembly in a controlled environment, no human contact during production
Where It Is Used

Applications And Buyers

Application Scenarios

  • Filtering large-volume pharmaceutical samples before HPLC injection
  • Preparing environmental and industrial water samples with high particulate loads
  • Handling viscous or protein-rich biological matrices in life-science research
  • Supporting high-throughput QC labs where filter change frequency impacts workflow
  • Replacing Millipore Millex filters in existing workflows without changing equipment or protocols

Who It Is For

  • Pharmaceutical and biotech labs requiring high-volume filtration with minimal downtime
  • Environmental testing labs processing large numbers of water and soil samples
  • Contract research organisations standardising on a single filter platform across multiple projects
  • Lab distributors seeking a cost-effective alternative to branded syringe filters with full compatibility
  • OEM partners needing a reliable base filter for private-label or co-branded consumables

Problems It Solves

  • Frequent filter changes due to small filtration area in standard 13 mm or 25 mm syringe filters
  • Filter housing bursting under pressure when handling viscous or high-particulate samples
  • Incompatibility with existing lab workflows when switching from Millipore Millex filters
  • Contamination risk from manual handling during filter assembly
  • Lack of sterile option in lower-cost syringe filters for sensitive analytical applications
Data

Specifications

Filter MediaNylon, PTFE, Hydrophilic PTFE, MCE, RC, CA, PES, PVDF, Hydrophilic PVDF, PP, GF
HousingMBS
Diameter33 mm
Filtration Area5.3 cm²
Pore Size0.1, 0.22, 0.45, 0.70, 1.0, 3.0, 5.0 micron
Sealing TechnologyInjection molding
Max Operating Pressure87 psi (6.0 bar) at 20°C
Inlet / OutletFemale luer lock / male luer slip
Packing100 pcs per pack

Materials

  • MBS housing
  • Membrane selected per application: Nylon, PTFE, Hydrophilic PTFE, MCE, RC, CA, PES, PVDF, Hydrophilic PVDF, PP, GF

Customization Options

  • OEM private-label printing and packing available through the Microlab OEM division
  • Custom membrane and pore size combinations can be arranged
  • Sterile and non-sterile variants available upon request
  • OEM contract manufacturing and membrane die-cut and packing services offered
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Automated membrane die-cutting
  • Injection moulding of MBS housing
  • Injection-moulded sealing of membrane into housing
  • Sterile or non-sterile packaging based on order
  • Final inspection and packing in 100-piece units

Quality Control

  • Membrane type and pore size verified against part number before assembly
  • Sealing integrity tested to 6.0 bar at 20°C
  • Visual inspection of housing and membrane alignment
  • Final check of packaging and labelling accuracy
Comparison

Compared With The Alternatives

Versus Standard 13 mm or 25 mm syringe filters

The 33 mm diameter and 5.3 cm² filtration area reduce clogging frequency and allow higher sample throughput without changing filters

Versus Solvent-bonded housings

Injection-moulded sealing eliminates adhesive in the flow path and maintains integrity under 6.0 bar pressure

Versus Millipore Millex syringe filters

Bestfil™ is specified as a direct replacement, so no method revalidation is required when switching

Versus Manual assembly filters

Automated production in a controlled environment reduces contamination risk and ensures consistent performance

Use Guide

How To Use It

  • Select membrane type based on sample chemistry: PTFE and PP for aggressive solvents, PES and MCE for aqueous samples, Nylon and RC for mixed phases
  • Choose pore size: 0.22 micron for routine HPLC clean-up, 0.45 micron for general filtration, 0.70 and 1.0 micron for high-particulate samples
  • Use 33 mm size for sample volumes exceeding 5 mL or when particle load is high
  • Attach syringe to female luer lock inlet, expel air, then filter at a steady rate
  • Discard first few drops if method is sensitive to membrane wetting solvent
  • Do not exceed 6.0 bar at 20°C; if pressure rises rapidly, switch to a coarser pore size or larger diameter
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

Is Bestfil™ a direct replacement for Millipore Millex syringe filters?

Yes. Bestfil™ is engineered to be a direct replacement for Millipore Millex syringe filters in the same 33 mm diameter and with the same inlet/outlet connections.

What is the filtration area of the 33 mm filter?

The effective filtration area is 5.3 cm², which is significantly larger than standard 13 mm or 25 mm filters.

What is the maximum operating pressure?

The filter can withstand up to 87 psi (6.0 bar) at 20°C, thanks to the injection-moulded sealing.

Are sterile versions available?

Yes. Bestfil™ is available in both sterile and non-sterile forms to meet different lab requirements.

Can I get these filters with my own brand label?

Yes. The Microlab OEM division offers private-label printing and packing for customers who need branded filters.

How are the filters packed?

Standard packing is 100 pieces per pack, with each housing clearly marked with membrane type and pore size.

Get A Quote For Bestfil Syringe Filter

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.

Language