Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
8-425 Sample Vial and Cap and Septa product photo 1
8-425 Sample Vial and Cap and Septa product photo 28-425 Sample Vial and Cap and Septa product photo 38-425 Sample Vial and Cap and Septa product photo 48-425 Sample Vial and Cap and Septa product photo 58-425 Sample Vial and Cap and Septa product photo 6
Autosampler Vial

8-425 Sample Vial and Cap and Septa

The 8-425 autosampler vial system is a standard ND8mm open-top screw glass vial designed for routine HPLC and GC analysis. It features a uniform flat bottom for stable placement in autosampler inserts, and is compatible with Agilent, Shimadzu, and Waters autosamplers. Pre-assembled caps and septa reduce handling and contamination risk, while PTFE/silicone septa provide reliable sealing and needle puncture performance. Available in clear and amber glass with optional writing areas on the vial body.

  • Standard ND8mm open-top screw design ensures compatibility with Agilent, Shimadzu, and Waters autosamplers
  • Uniform flat bottom provides stable seating in autosampler inserts, reducing run-to-run variability
  • Pre-assembled caps and septa minimize handling and contamination during sample loading
  • PTFE/silicone septa offer consistent sealing and easy needle puncture, reducing septa carry-over
Key Benefits

What This Product Gives You

  • Standard ND8mm open-top screw design ensures compatibility with Agilent, Shimadzu, and Waters autosamplers
  • Uniform flat bottom provides stable seating in autosampler inserts, reducing run-to-run variability
  • Pre-assembled caps and septa minimize handling and contamination during sample loading
  • PTFE/silicone septa offer consistent sealing and easy needle puncture, reducing septa carry-over
  • Pre-slit septa reduce needle penetration force and lower the risk of septa fragments entering the sample
  • Clear and amber glass options allow for visual sample monitoring and light-sensitive sample protection
  • Vial volume: 1.5 ml and 2 ml
  • Neck type: 8-425 screw top
  • Vial size: 12 mm diameter × 32 mm height
  • Vial material: Glass
  • Vial color: Clear or Amber
  • Writing area available on select vial models
  • Septa options: PTFE/silicone, pre-slit, bonded PTFE/silicone, or white PTFE
  • Septa thickness: 1.5 mm (standard), 0.25 mm (white PTFE only)
  • Pre-assembled cap and septa configuration reduces handling and contamination risk
  • Flat bottom design ensures stable placement in autosampler inserts
Where It Is Used

Applications And Buyers

Application Scenarios

  • Routine HPLC and GC sample preparation in pharmaceutical and environmental testing labs
  • High-throughput analysis where consistent vial seating and reliable septa performance are critical
  • Sample storage and transport in labs using autosamplers with tight space constraints
  • Analysis of light-sensitive compounds requiring amber vials to prevent degradation
  • Laboratories standardising on a single vial format across multiple instrument platforms

Who It Is For

  • Pharmaceutical QC labs running high-volume HPLC and GC methods with tight throughput targets
  • Environmental and food testing labs handling diverse sample matrices requiring consistent vial performance
  • Contract research organisations managing multiple instrument types and needing interchangeable vials
  • Lab distributors sourcing a complete, pre-assembled vial system with consistent quality and delivery

Problems It Solves

  • Vials not seating properly in autosampler inserts due to uneven or domed bottoms
  • Septa fragments contaminating samples when using non-pre-slit or poorly designed septa
  • Inconsistent needle puncture force leading to needle damage or poor injection reproducibility
  • Need to source vials, caps, and septa from separate suppliers with different quality control
  • Light-sensitive samples degrading in clear vials during storage or analysis
Data

Specifications

Volume1.5 ml, 2 ml
Neck Type8-425
Size12 mm × 32 mm
Vial MaterialGlass
Vial ColorClear, Amber
Writing AreaAvailable on SV0812C and SV0812A
Cap MaterialPP
Septa MaterialPTFE/Silicone, Pre-slit, Bonded PTFE/Silicone, White PTFE
Septa Thickness1.5 mm (standard), 0.25 mm (white PTFE only)
Packing100 pieces per pack
CompatibilityAgilent, Shimadzu, Waters autosamplers

Materials

  • Glass vial
  • PTFE/silicone septa
  • Pre-slit or bonded PTFE/silicone septa
  • White PTFE septa (0.25 mm)

Customization Options

  • Choice of clear or amber glass vials
  • Vials with or without writing area
  • Multiple septa types: PTFE/silicone, pre-slit, bonded, or white PTFE
  • OEM private-label packing and branding available through the Microlab OEM division
  • Custom packaging configurations possible for bulk orders
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Glass vial manufacturing and annealing
  • Die-cutting and assembly of septa
  • Pre-assembly of caps and septa onto vials
  • Quality inspection of assembled units
  • Packing in PP boxes at 100 pieces per pack

Quality Control

  • Glass vials inspected for cracks, bubbles, and dimensional consistency
  • Caps verified for proper fit and material integrity
  • Septa checked for uniform thickness and pre-slit alignment
  • Pre-assembled units tested for sealing integrity and needle puncture performance
  • Final inspection against packing and part number accuracy
Comparison

Compared With The Alternatives

Versus Vials with domed bottoms

The flat bottom ensures consistent seating in autosampler inserts, reducing run-to-run variability and preventing vial tilt during injection.

Versus Separate caps and septa

Pre-assembled units reduce handling, lower contamination risk, and ensure correct pairing of cap and septa.

Versus Non-pre-slit septa

Pre-slit septa reduce needle penetration force and lower the risk of septa fragments entering the sample.

Versus Single-use vials from multiple suppliers

A single source for vials, caps, and septa ensures consistent quality, compatibility, and delivery.

Use Guide

How To Use It

  • Select clear vials for visual inspection of samples or amber vials for light-sensitive compounds
  • Use vials with writing areas when labelling samples directly on the vial body
  • Choose pre-slit septa for easier needle penetration and reduced needle wear
  • Use bonded PTFE/silicone septa for applications requiring higher sealing integrity
  • Ensure the vial is seated flat in the autosampler insert before injection
  • Do not over-tighten the cap to avoid damaging the septa or deforming the cap
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

Are these vials compatible with Agilent, Shimadzu, and Waters autosamplers?

Yes. The 8-425 neck type and ND8mm design are standard across Agilent, Shimadzu, and Waters autosamplers.

What is the difference between the clear and amber vials?

Clear vials allow visual inspection of samples. Amber vials protect light-sensitive compounds from degradation.

Do you offer vials with writing areas?

Yes. Models SV0812C and SV0812A include a writing area on the vial body.

What septa types are available?

Available septa include PTFE/silicone, pre-slit, bonded PTFE/silicone, and white PTFE (0.25 mm).

Can I order these with my own branding?

Yes. The Microlab OEM division supports private-label packing and custom branding for bulk orders.

How are the vials packed?

Standard packing is 100 pieces per pack in PP boxes. Pre-assembled caps and septa are included.

Get A Quote For 8-425 Sample Vial and Cap and Septa

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.

Language