Composite Station Post Insulators FZS-10/8.9

Composite Insulators · Station Post

Composite Station Post Insulators FZS-10/8.9

Key Data

Shed Diameter140 & 114mm
Shed Spacing30mm
Section Length250mm
Dry Arcing Distance165mm
Leakage Distance450mm
Cantilever Strength8.9kN

Huaci engineers provide OEM service to meet the varying needs from customers.

Specifications

All values as published in the Huaci catalogue.

Dimensions
Shed Diameter140 & 114mm
Shed Spacing30mm
Section Length250mm
Dry Arcing Distance165mm
Leakage Distance450mm
Mechanical Values
Cantilever Strength8.9kN
Tension Strength38kN
Torsion Strength791Nm
Compression Strength44.5kN
Electrical Values
Low Frequency Dry Flashover Voltage85kV
Low Frequency Wet Flashover Voltage55kV
Critical Impulse Flashover Voltage, Positive125kV
Critical Impulse Flashover Voltage, Negative200kV
Packing and Shipping Data
Net Weight, Approximate2.2kg

Standards

Huaci strictly comply with GB, ANSI, BS, DIN, AS and IEC standard designs, applicable to power transmission lines and substations.

Quality Systems

ISO 9001:2015 Quality Management, ISO 14001:2015 Environment Management and ISO 45001:2018 Occupational Health And Safety Management System certificates.

Export Record

Huaci products are exported to more than 40 countries and have performed well in a variety of global environments.

FAQ

About Composite Station Post Insulators FZS-10/8.9

What is the cantilever strength of Composite Station Post Insulators FZS-10/8.9?

The published cantilever strength of Composite Station Post Insulators FZS-10/8.9 is 8.9kN.

What does Composite Station Post Insulators FZS-10/8.9 weigh?

The published net weight is 2.2kg each.

What is the leakage distance of Composite Station Post Insulators FZS-10/8.9?

The published leakage distance is 450mm.

Which design standards does Huaci comply with?

Huaci strictly comply with GB, ANSI, BS, DIN, AS and IEC standard designs, applicable to power transmission lines and substations.

What system voltages are covered?

Huaci specialises in insulator manufacture up to 500 kV AC and 400 kV DC system voltages.

Is OEM or customised production available?

Yes. Huaci engineers are able to provide OEM service to meet the varying needs from customers and assist the customers to develop their market better.

Which quality certificates does the factory hold?

Quality Management System Certificate ISO 9001:2015, Environment Management System Certificate ISO 14001:2015 and the Occupational Health And Safety Management System Certificate ISO 45001:2018.

Request A Quotation For Composite Station Post Insulators FZS-10/8.9

Send the quantity and destination port and Huaci will reply with pricing, packing details and lead time.